ALARMS
M-Series processors are equipped with audible alarms.
1. The Constant Tone signals lack of incoming water pressure.
(-------------------------------------------------------- Constant Tone)
Check incoming feed pressure to ensure a minimum of 20 psi.
Water pressure below 20 psi will trigger alarm. Incoming feed water
pressure must be raised.
2. One second intermittent beeping signals systems is in Auto Bypass.
(-- -- -- -- -- -- -- -- -- -- -- -- -- -- One second intermittent tone).
During initial start up with empty tank, the system will automatically be in
Auto-Bypass until the tank has completely filled. The Auto by pass will only be
triggered if the tank pressure drops below 5 psi (Pressure tank systems). Float
switch controlled Atmospheric tank systems with float switches, remain on until
tank is full and processor has turned off automatically.
3. Two second intermittent beeping indicates possible wiring problem or
problem with installation of Float Switches.
(---- ---- ---- ---- ---- ---- Two second intermittent tone.)
Solution:
Check to ensure labeled
electrical cables are connected
to corresponding float
switches.
Check conductivity of wire to
ensure no broken wire cables
exist.
Verify Float position per
drawing to the right.