Turn off the cold water supply to the faucet by turning the angle stop valve completely off.
Open cold water sink faucet to relieve pressure.
Step 7
Step 8
Choosing the conguration that ts your plumbing, attach the adapt-a-valve as illustrated in
the four photos above.
Adapt-a-Valve Installation
Do not use Teon tape with the Adapt-a-Valve.WARNING:
Caution:
Water supply line to the system must be from the cold water supply line only.
Hot water will severely damage your system.
3/8” Conguration
(With Brass Fittings)
* Insert White Washer
1/2” Conguration
(Without Brass
Fittings)
*White
Washer
Hot
Supply
Cold
Supply
Hot
Supply
Cold
Supply
Verify contents prior to installation:
( 1 ) - Plastic Adapt-a-Valve with black collet
( 1 ) - Brass Adapter no washer
( 1 ) - Brass Adapter with black washer
( 1 ) - White rubber washer
Make sure that the black collet is installed in to the 1/4” opening on the Adapt-a-valve.
Don’t forget to install the white compression washer with the 3/8” conguration.
Brass adapter (A) does not need to be tightened with a wrench, only nger tight.
Black
Collet
A
TIPS:
A
White
Washer
Reverse Osmosis Module Mounting
Step 9
Do not cut any RO system tubes at this timeNote:
Determine best location for the RO module to be mounted to allow
for future system maintenance. Using the mounting holes on the
bracket, mark the location for the mounting screws on the cabinet
wall under the sink. In the parts bag, locate the two self tapping
screws. Using an electric drill with a Phillips bit, screw them into
the cabinet at the marked location. Hang the module on the screws
using the mounting holes in the bracket